易光科技LED驱动器完成HALT和HASS测试(一)
Stress Type |
Chamber Set-point Level |
Temperature LOL |
-30°C |
Temperature LDL |
-50°C |
Temperature UOL |
+ 120°C |
Temperature UDL |
+ 160°C |
Vibration OL |
60 Grms |
Vibration DL |
65 Grms |
Setpoint (°C) |
Functional Test Result (Pass/Fail) |
Notes |
+20 |
Pass |
Sample no.1 was applied in this test. |
+10 |
Pass |
|
0 |
Pass |
|
-10 |
Pass |
|
-20 |
Pass |
|
-30 |
Pass |
|
-40 |
Pass |
|
-50 |
Pass |
|
-60 |
Pass |
|
-70 |
Pass |
|
-80 |
Fail |
|
-90 |
Fail |
At -90°C, the LED light panel lighted up with intermittent weak light flashes. |
+20 |
Pass |
It recovered at +20°C. |
-80 |
Fail |
The LED light panel lighted up with intermittent light flashes with normal light intensity. |
+20 |
Pass |
It recovered at +20°C. Cold operating limit was found at -70°C. |
-100 |
Fail |
The LED light panel lighted up with intermittent weak light flashes. |
+20 |
Pass |
It recovered at +20°C. Cold destruct limit was found at <-100°C. |